5 door clearances are within allowable limits.
Fire door inspection checklist template.
Fire door inspection checklist.
Leaf the door leaf should sit flush with the door stop and without any distortion.
4 no missing or broken parts.
To ensure the safety of a building s occupants regular checks must be performed on all fire doors.
To help you implement the advice you are given during the week checkmate fire has compiled a downloadable fire door inspection checklist.
6 door closer spring hinges are operational and d oor is self closing.
Swinging doors with builders hardware or fire door hardware 13 point inspection.
View the vision panel and glass from both sides of the door.
Open the door about halfway let go and see.
For best results use a checkmate fire gap gauge or use a 1 coin to give a feel for scale this is about 3mm thick.
No open holes or breaks exist in surfaces of either the door or frame.
And you don t need any programming knowledge.
Open the door and take a look at the hinges.
Although the code does not require anyone to have special training to inspect or maintain facility doors this program will help ensure you are in compliance when surveyed and will help you.
Still a checkmate fire gap gauge take a look at the edges of the door and frame.
Fire doors are fire resistant equipment that need to be checked regularly to make sure they still offer protection to other parts of the building.
Fire door inspection form template stay safe with a pre designed fire door inspection form sample that can be easily modify to serve your purpose.
Here is a handy checklist of the essential features that should be checked.
Labels are clearly visible and legible.
Ensure that the door is free from any dents holes or other damage and that any veneer is still.
We are certified to perform detailed 13 points fire doors inspection.
Section 18 2 2 2 1 19 2 2 2 1 requires compliance with section 7 2 1 and section 7 2 1 15 2 requires compliance with nfpa 80 standard.
Fire door safety week 2018 which runs from september 24th to 30th is designed to promote awareness of the importance of choosing the right fire doors and ensuring they are properly installed and maintained.
Door inspection and maintenance workshop authorities having jurisdiction ahjs are looking at door maintenance programs in new and different ways.
The 2012 edition of the life safety code nfpa 101 requires facilities to complete annual fire and smoke door inspection and testing.
Our fire smoke door experts will provide a thorough inspection of all the doors in the building to ensure they are safe and complying with the nfpa code and prepare a detailed report on the condition and function of the fire door on your facilities.
Glazing vision light frames and glazing beads are intact and securely fastened in place if so equipped.
Labels every fire door should display a bwf certifire fire door scheme label usually found on the top edge of the door.
3 door frame and hardware are in proper working order.