Concrete mix for footing to be 1 part cement to 2 5 parts sand to 3 5 parts gravel with a maximum of 7 5 gallons of water per sack of cement minimum f c 2 500 psi.
City of los angeles standard retaining wall detail.
Retaining or slough wall 4 foot high or less 178 kb view.
Build safe well and fast with the city of los angeles department of building and safety.
Retaining walls heights are also regulated by the zoning laws of the city as follows.
Concrete block retaining wall h 6 0 max b3761 1 b3761 2.
Metal bin type retaining wall.
Alternative design procedures justified in a geotechnical report may also be approved.
The standard plans are divided into several series.
Acceptable engineering criteria for retaining wall design.
Residential code section r404 4 specifies that retaining walls shall be designed to ensure.
1149 s broadway suite b 10 los angeles ca 90015 phone.
Plumbing plan check correction list for 2017 codes 422 kb view.
Design of retaining walls as presented in this bulletin are in accordance with sections 1610 1 and 1807 2 of the city of los angeles building code labc.
Back to standard plans main index.
Page 1 of 2 retaining or slough wall 4 0 high or less.
County of los angeles department of public works building and safety division based on the 2011 lacrc 1014 r404 4 article 1 10 25 12 page 1 of 7 design of retaining walls issue.
6 concrete block masonry wall detail 6 0 height maximum general specifications.
City of los angeles electrical plan check correction list.
As a covered entity under title ii of the americans with disabilities act the city of los angeles does not discriminate on the basis of disability and upon request will provide reasonable accommodation to ensure equal access to its programs services and activities.
Concrete block units to have vertical continuity of the cells unobstructed.
213 847 0700.
Concrete block units shall conform to astm c90.
Soil lateral loads labc 1610 1 general.
If any information on any of the standard plans is not legible it is the user s responsibility to obtain a legible copy from the bureau of engineering vault located at.
Disabled access standard details notes for commercial buildings.
Reinforcing steel shall be deformed steel conforming to a s t m.
Concrete block units to be staggered running bond.
Concrete block units to be standard 8 x8 x16 units conforming to ubc standard 21 4.
Informational page for pre approved standard plans.
Each series contains several standard plans.
Multiple cover details for sanitary sewer manholes.
San diego municipal code chapter 14 article 2.